RETIRED ›
This product is no longer available and has been replaced by: CR300,CR310. Some accessories, replacement parts, or services may still be available.
CR200X Datalogger
Services Available

Overview

The CR200X, our smallest lowest-cost datalogger, provides stand-alone operation in harsh, remote environments. It reads input from one or two sensors, then transmits the data using communication peripherals. CRBasic, its full programming language, supports simple or complex programming. Multiple CR200Xs can be configured as a network, or units can be deployed individually.

Note: End-of-Life Product: For new projects, the CR300-series dataloggers are recommended instead of the CR200X-series dataloggers. The CR300-series dataloggers build on the successful features of the CR200X-series dataloggers, while adding new features. The CR200X-series dataloggers will continue to be available for customers with existing CR200X networks until 16 January 2018.

Read More

Benefits and Features

  • Ideal applications include wind energy, rural water, water level/flow, aquaculture, water quality
  • Campbell Scientific’s smallest, lowest cost data logger
  • Gas Discharge Tube (GDT) protected inputs
  • Optimal for measuring one or two simple sensors
  • Makes SDI-12, single-ended analog, pulse, switch closure, and bridge measurements
  • Battery-backed clock that ensures accurate time is maintained while data logger is disconnected from battery power
  • Program with LoggerNet, PC400, or Short Cut to fit your setup
  • PakBus, Modbus, and SDI-12 protocols supported

Images

CR200x standard view top
CR200x standard view bottom
CR200x standard view front
CR200x standard view iso
CR200x standard view left
CR200x standard view right

3D/CAD Files:

Technical Description

The CR200X has several input channels for measuring a variety of sensors. Gas discharge tubes provide rugged electrostatic discharge protection for the inputs.

The CR200X does not make differential measurements and is not compatible with SDM devices, multiplexers, or thermocouples (refer to the Compatibility information for compatible sensors, peripherals, and software). Recalibration services are not offered for the CR200X datalogger.

Specifications

-NOTE- Note: Additional specifications are listed in the CR200X-Series Specifications Sheet.
Maximum Scan Rate 1 Hz
Analog Channels
  • The single-ended analog inputs can also be used as control ports.
  • 5 single-ended (no differential) individually configured
Pulse Count Channels 2
Switched Excitation Channels 2 voltage
Digital Ports
  • Certain digital ports can be used to count switch closures.
  • 2 I/O
Communication Ports 1 RS-232
Switched Battery Port 1
Input Voltage Range 0 to 2500 mV
Analog Voltage Accuracy ±(0.25% of reading + (1.2 mV)x(offset)) at -40° to +50°C
Analog Voltage Resolution 0.6 mV
A/D Bits 12
Operating Temperature -40° to +50°C
Power Requirements 7 to 16 Vdc
Typical Current Drain
  • ~0.2 mA (quiescent)
  • ~3 mA (active)
Clock Accuracy
  • 8.2 min./month (@ -40° to +50°C)
  • 1 min./month (@ +25°C)
Protocols Supported PakBus (leaf node only), SDI-12
CE Compliance Standards to which Conformity Is Declared IEC61326:2002
Warranty 3 years
Dimensions 14.0 x 7.6 x 4.8 cm (5.5 x 3.0 x 1.9 in.)
Weight 242 g (8.5 oz)

Memory

Final Storage 512 kB of flash memory for approximately 125,000 data points
Operating System 106 kB of flash memory
Intermediate Storage 8 kB of SRAM for communication buffers, calculations, variables, etc.

Compatibility

Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.

Measurement and Control

Product Compatible Note
AM16/32B
AM25T

Sensors

Product Compatible Note
014A
03002
034B
05103
05103-45-L (retired)
05106
05305-L
107
108
109
109SS
110PV (retired)
237 (retired)
255-100
27106T
43347
52202-L
A100LK-L
CMP11
CMP21
CMP3-L
CMP6 (retired)
CS100
CS106
CS11-L
CS215 (retired)
CS300 (retired)
CS451
CS456
CS475 (retired)
CS475A
CS476 (retired)
CS477 (retired)
CS511
CS526
CS547A-L
CS616
CS625 (retired)
CS650
CS655
CS700
CSAT3 (retired)
CSIM11-L
CSIM11-ORP-L
ENVIROSCAN (retired)
HC2S3 (retired)
HMP155A-L
HMP60
LWS
OBS-3+ (retired)
OBS300 (retired)
OBS500 (retired)
OBS501
SR50A-L
WINDSONIC1
WINDSONIC4
WXT520 (retired)

Software

Product Compatible Note
LoggerNet Version 2.1 or higher
PC200 (retired)
PC400 Version 1.0 or higher
PCONNECT (retired) Version 3.0 or higher
PCONNECTCE (retired) Version 2.0 or higher
Short Cut

Additional Compatibility Information

Communications

The CR200X can communicate with a PC via direct connect, NL201 Network Link Interface, NL240 Wi-Fi Network Link, MD485 multidrop modem, and digital cellular modems. Data can be viewed on an iOS device, an Android device, CD295 DataView II Display, or a user-supplied PDA. To use an iOS or Android device, go to the Apple Store or Google Play and download our LoggerLink Mobile Apps free of charge. User-supplied PDAs require either PConnect or PConnectCE software.

Measurement & Control Peripherals

The CR200X is not compatible with SDM devices and multiplexers.

Sensors

The CR200X can measure a variety of sensors including SDI-12 sensors and 4 to 20 mA sensors. It cannot make differential measurements and is not compatible with the freezing-rain/ice, fuel moisture/temperature, geographic position, present weather, soil heat flux, soil matric water potential, and strain sensors listed on our price lists.

Enclosures

Applications with minimal power requirements can use the ENC200 enclosure to house the data logger and the pn 16869 sealed rechargeable battery. The ENC200 cannot house a barometer or a battery that is larger than the pn 16869. However, an ENC10/12 or ENC12/14 enclosure is adequate for most CR200X-based systems.

Power Supplies

The CR200X uses an external power supply and has a built-in regulator. When connected to the on-board charging circuit, the sealed rechargeable battery should be 7 A h or smaller. Using larger batteries with the data logger's built-in charger may result in excessive PC board heating. This is especially a concern when the battery is deeply discharged or failing with a shorted cell. Campbell Scientific also recommends that solar panels be 10 W or less and wall chargers be 1 A or smaller.

Downloads

CR200X Series OS v.04 (1.29 MB) 22-09-2015

Execution of this download installs the Operating System and Compiler on your computer for the following dataloggers:CR200X, CR206X, CR211X, CR216X and CR295X.  It also updates the support files for the CRBasic Editor.  

Note: Newer CR206X dataloggers (serial # ≥ 19122) and newer CR211X dataloggers (serial # ≥ 19143) have 250 mW radios that must use OS 3 or higher for their datalogger operating system.

View Revision History

FAQs for

Number of FAQs related to CR200X: 38

Expand AllCollapse All

  1. Not directly. If the CS15-L is connected to a CR200(X) datalogger, the data logger can take the ac measurement and control a solid-state relay based on some threshold within the data logger program. The solid-state relay can then control other relays, solenoids, or motor starters. (Use of a solid-state relay is preferred because the data logger can trigger it with a small 5 Vdc mA signal.) For more information, see the “Measurement and Control Peripherals” section of the operator’s manual.

  2. Yes. The simplest method is to use conditional program statements that execute most of the code based on time. For example, the data could be scheduled to log at 6 a.m. and finish at 8 p.m. using CRBasic instructions such as IfTime(). Another option is to use an IfThen/EndIf construction that does a logical test of light-level measurements based on a light sensor. An additional option is to use calculated sunrise and sunset times along with a combination of RealTime() and Case instructions.

    For more information, see the “Decisions, Decisions, Decisions…” article. 

  3. Current data loggers compatible with the BMP5 Direct SDK are the CR200X-series, CR1000, CR3000, CR800, and CR850.

    Retired compatible data loggers include the CR10X-PB, CR23X-PB, and CR510-PB. These data loggers must have the optional PakBus operating system installed, which is available on the Downloads page of our website.

  4. The maximum cable length depends on the interface being used.

    • RS-232 connections will reach 15 m (50 ft).
    • RS-485 connections go beyond 610 m (2,000 ft).
    • IP connections can be routed worldwide. 
  5. Technically, the SRM-5A is compatible with the CR200X-series dataloggers, but it is more complicated to use it with these data loggers. To use a SRM-5A with a CR200X-series datalogger, the SRM-5A must be in the DTE position on the station modem. In addition, user-supplied adapters and gender changers are needed to complete the connections between the SRM-5A and the RS-232 port of the data logger. Contact Campbell Scientific for more information.

  6. If small amounts of data are transferred per transmission, it will not be a problem. Larger amounts of data can overrun buffers in the modem, causing lost data. In that situation, lower the baud rate on the data logger to avoid the issue.

  7. A data logger can be programmed to initiate data transfer by using the SendVariables() or ModemCallback() instruction in CRBasic. 

    NOTE: These instructions are not supported in the CR200X operating system.

  8. They use the same protocol, but the CR800 PakBus protocol is less limited in its capability.

  9. The CR200X-series and the retired CR200-series dataloggers are NOT compatible with SDMs or multiplexers. If more channels are needed or may be needed in the future, consider purchasing a CR800, CR850, or CR1000 instead.

  10. Yes. There are low-level instructions for the CR800, CR850, CR1000, and CR3000 available in CRBasic that make this possible. The CR200X-series dataloggers do not have the ability to manipulate string type data.

Case Studies

Virginia: ALERT System
In the late 1970s, the National Weather Service implemented the Integrated Flood Observing and Warning......read more

Privacy Policy Update

We've updated our privacy policy.  Learn More

Cookie Consent

Update your cookie preferences.  Update Cookie Preferences