CR1000X OS 8.01 Software and OS Revision Histories

Submit an enquiry Submit an enquiry
  • CR1000X(e) OS 8.2.1
    26 change(s) - 07-04-2025
  • CR1000X(e) OS 8.01
    4 change(s) - 26-09-2024
  • CR1000X(e) OS 8.00
    24 change(s) - 12-09-2024
  • CR1000X(e) OS 7.02
    1 change(s) - 19-03-2024
  • CR1000X(e) OS 7.01
    4 change(s) - 15-12-2023
  • CR1000X(e) OS 7.0
    40 change(s) - 16-11-2023
  • CR1000X(e) OS 6.02
    3 change(s) - 06-03-2023
  • CR1000X(e) OS 6.01
    6 change(s) - 28-09-2022
  • CR1000X(e) OS 6.00
    35 change(s) - 17-05-2022
  • CR1000X(e) OS 5.02
    1 change(s) - 06-12-2021
  • CR1000X(e) OS 5.01
    7 change(s) - 24-05-2021
  • CR1000X(e) OS 5.00
    42 change(s) - 03-03-2021
  • CR1000X(e) OS 4.02
    5 change(s) - 31-03-2020
  • CR1000X(e) OS 4.01
    3 change(s) - 04-03-2020
  • CR1000X(e) OS 4.00
    36 change(s) - 26-02-2020
  • CR1000X(e) OS 3.02
    6 change(s) - 22-04-2019
  • CR1000X(e) OS 3.01
    2 change(s) - 13-03-2019
  • CR1000X(e) OS 3.00
    30 change(s) - 31-01-2019
  • CR1000X(e) OS 2.00
    67 change(s) - 27-06-2018
  • CR1000X(e) OS 1.02
    6 change(s) - 21-12-2017
  • CR1000X(e) OS 1.01
    15 change(s) - 18-10-2017

Back To Update List

CR1000X(e) OS 8.01
Updated: 26-09-2024

  1. (New Features) CRITICAL – See Revision notes for OS version CR1000X 8.00.
  2. (Major) Fixed an issue introduced in CR1000X version 8.00 where SerialOpen() failed to open communication ports on COMC1 and COMC3.
  3. (Minor) Corrected the handling of millisecond units for TimeIntoInterval in MQTTPublishTable().
  4. (Minor) Fixed an issue where rotating TLS certificates for Campbell Cloud caused the data logger to miss a byte of data on the COMC port due to port unnecessary being reconfigured.
CAMPBELL SCIENTIFIC UNITED KINGDOM

  • Home
  • Products
  • Solutions
  • Support
  • About
  • Newsroom
  • Corporate Blog
  • User Forum
  • Videos & Tutorials
  • Contact Us
  • Customer Center
  • Feedback
  • ISO Certifications
  • Site Map

country map

80 Hathern Road
Shepshed,
Loughborough
LE12 9GX
UNITED KINGDOM

Campbell Scientific Logo


Feedback? Feedback? © 2025 Campbell Scientific United Kingdom