Overview

The SC-CPI is an interface between the serial port of later-model Campbell Scientific dataloggers (CR800/850, CR1000, and CR3000) and our new Campbell distributed modules (CDMs). The CDMs use the new CAN peripheral interface (CPI), and the SC-CPI allows the dataloggers listed above to connect to the CDM's CPI port. Future dataloggers will have CPI connections and will not need a bridge, but with the SC-CPI our current line of dataloggers will be able to take advantage of our CDM technology.

Benefits and Features

  • Enables a CR800, CR850 CR1000, or CR3000 to be part of a CPI/CDM network
  • Provides detailed CPI communication diagnostics
  • Supports monitoring of the serial or CPI load
  • Indicates if CPI frame errors occur
  • Provides information about each CPI module that it detects in its network

Images

SC-CPI shown with connector and 29526 cable attached (a Ships With item)
SC-CPI shown with connector and 29526 cable attached (a Ships With item)
SC-CPI shown with connector and 29526 cable attached (a Ships With item)

Specifications

Temperature Range
  • -25° to +50°C (standard)
  • -55° to +85°C (extended)
Current Drain 50 mA (active)
Dimensions 15.94 x 7.49 x 3.18 cm (6.28 x 2.95 x 1.25 in.) including ground lug
Weight 0.188 kg (0.415 lb)

Connectors

CPI RJ45
Serial Connect to Data Logger Screw terminal
Computer Configuration via Device Configuration Utility USB

Compatibility

Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.

Dataloggers

Product Compatible Note
CR1000 (retired)
CR200X (retired)
CR216X (retired)
CR3000
CR800
CR850
CR9000X (retired)

Additional Compatibility Information

Data Logger Considerations

A 5-conductor cable connects the data logger to the SC-CPI, and an Ethernet cable connects the SC-CPI to the CDM.

The data logger operating system must be version OS 26.

Resources and Links


FAQs for

Number of FAQs related to SC-CPI: 2

  1. To communicate with CDM devices using the CPI protocol, the CR3000, CR1000, CR850, and CR800 dataloggers require an SC-CPI device. Only one SC-CPI device per data logger is required. It is expected that the design of future Campbell Scientific data logger products will work with CPI-based modules directly.

  2. The communications protocol used by CDM devices is the CAN Peripheral Interface (CPI), which includes methods that are proprietary to Campbell Scientific.